  data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36-60 vdc input; 9.6v output; 240 w * ul is a registered trademark of underwriters laboratories, inc. ? csa is a registered trademark of canadian standards association. ? vde is a trademark of verband deutscher elektrotechniker e.v. ** iso is a registered trademark of the international organization of standards document no: ds06-113 ver. 1.03 pdf name: euk240_series_ds.pdf applications ? distributed power architecture ? wireless networks ? optical and access networks equipment ? enterprise networks options ? negative logic, remote on/off ? pin length features ? compliant to rohs eu directive 2002/95/ec (-z versions) ? compliant to rohs eu dir ective 2002/95/ec with lead solder exemption (non-z versions) ? high efficiency ? 96% at 9.6v, full load ? excellent thermal performance: 240w at vin=55vdc, 55oc at 1m/s (200lfm) 240w at vin=60vdc, 60oc at 1.5m/s (300lfm) ? industry standard eighth brick: 57.9 mm x 23.6mm x 11.0 mm (2.28 in x 0.93 in x 0.44 in) ? cost-efficient open frame design ? low output voltage ripple and noise ? positive remo te on/off logic ? output over-current protection, auto-restart ? input over-voltage protection, auto-restart ? input under-voltage lockout ? over-temperature prot ection, auto-restart ? operating temperature range (-40c to 85c) ? iso** 9001 certified manufacturing facilities ? basic insulation (100% fa ctory test to 1500vdc) ? ul * 60950-1 recognised, csa ? c22.2 no. 60950- 1-03 certified, and en 60950-1 ( vde ? 0805: 2001- 12) licensed description the euk240-series dc-dc converters are single-output power modules designed to support intermediate bus applications using discrete/modular point of load (pol) converters. the output is unregulated and a fixed 5:1 ratio is maintained between the input and output voltages. by taking advantage of the absence of regulation, high efficiency topologies operated at fixed duty cycles can be employed leading to low cost open frame modules. the output is fully isolated from the input, allowing versatile polarity conf igurations and grounding connections. the high efficiency of this converter leads to lower power dissipation. built- in filtering for both input and output minimizes the need for external filtering. the module package dimensions are 59.7 mm x 23.6 mm x 11.0 mm (2.28 in x 0.93 in x 0.44 in.). standard features include remote on/off, input over-voltage, output over-curr ent and over-temper ature protection. rohs compliant
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 2 absolute maximum ratings stresses in excess of the absolute maximum ratings can ca use permanent damage to the device. these are absolute stress ratings only, functional operation of the device is not im plied at these or any other c onditions in excess of those given in the operations sections of the data sheet. exposur e to absolute maximum ratings for extended periods can adversely affect the device reliability. parameter device symbol min max unit input voltage continuous all v in -0.3 60 vdc non-operating condition all -0.3 75 vdc operating ambient temperature all t a -40 85 c storage temperature all t stg -55 125 c i/o isolation voltage (100% factory tested) all v iso ? 1500 vdc electrical specifications unless otherwise indicated, specificati ons apply over all operating input vo ltage, resistive load, and temperature conditions. parameter device symbol min typ max unit operating input voltage all v in 36 48 60 vdc maximum input current (v in =0 to 60vdc, p o =p o, max ) all i in,max 5 adc inrush transient all i 2 t 1 a 2 s input reflected ripple current, peak-to-peak (5hz to 20mhz, 12 h source impedance; t a 25 o c, c in = 33 f) all ? 50 ? map-p input ripple rejection (120hz) all ? 14 ? db caution: this power module is not internally fused. an input line fuse must always be used. this power module can be used in a wide variety of appl ications, ranging from simple standalone operation to being part of complex power architecture. to preserve maximum flex ibility, internal fusing is not included, however, to achieve maximum safety and system protection, always us e an input line fuse. the safety agencies require a fast- acting fuse with a maximum rating of 15 a (see safety cons iderations section). based on the information provided in this data sheet on inrush energy and maximum dc input curr ent, the same type of fuse with a lower rating can be used. refer to the fuse manufacturer?s data sheet for further information.
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 3 electrical specifications (continued) parameter device symbol min typ max unit output voltage set-point all v o, set 9.6 vdc (v in = v in, min , i o = i o, max , t a =25c) output voltage all v o 6.0 ? 12.0 vdc (over all line, load, and temp conditions until end of life) output regulation line (v in = v in, min to v in, max ) all ? ? ? ? ? f ceramic // 10 f tantalum capacitor) rms (5hz to 20mhz bandwidth) all ? 33 65 mv rms peak-to-peak (5hz to 20mhz bandwidth) all ? 100 150 mv pk-pk external capacitance all c o,max 0 ? 5000 f output power p o 240 w output current all i o 0 ? 34 a dc output current limit inception (hiccup mode) all i o, lim ? 32 a dc efficiency all ? 96 ? % v in = 48v, t a =25c, i o = i o, max switching frequency all f sw 130 240 khz dynamic load response (di o /dt= 0.1a / s; v in = v in, nom ; t a =25c) load change from i o = 50% to 75% of i o,max peak deviation all v pk ? 400 ? mv settling time (v o <10% peak deviation) all t s ? 0.2 ? ms load change from i o = 50% to 25% of i o,max peak deviation all v pk ? 400 ? mv settling time (v o <10% peak deviation) all t s ? 0.2 ? ms isolation specifications parameter min typ max unit isolation capacitance ? 1000 ? pf isolation resistance 10 ? ? m general specifications parameter min typ max unit calculated mtbf (i o = 80% of i o, max , t a =40c) 2,511,340 ? hours weight ? 32.5 (1.15) ? g (oz.)
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 4 feature specifications unless otherwise indicated, specificati ons apply over all operating input vo ltage, resistive load, and temperature conditions. see feature descriptions for additional information. parameter device symbol min typ max unit remote on/off signal interface (v in =v in, min to v in, max ; open collector or equivalent, si g nal referenced to v in- terminal ) negative logic: device code suffix ?1? logic low = module on, logic high = module off positive logic: no dev ice code suffix required logic low = module off, logic high = module on logic low - remote on/off current all i on/off ? ? 1.0 ma logic low - on/off voltage all v on/off -0.3 ? 0.8 v dc logic high voltage ? (typ = open collector) all v on/off 2.0 ? ? ? 0.7 ma maximum voltage allowed on on/off pin v on/off ? ? 13.5 v dc turn-on delay and rise times (i o =80 % i o, max , t a = 25 o c) case 1: on/off input is set to logic high and then input power is applied (delay from instant at which v in = v in, min until v o =10% of v o,nom ) all t delay D 10 D msec case 2: input power is applied for at least one second and then the on/off input is set to logic high (delay from instant at which von/off = 0.9v until v o =10% of v o, set ) all t delay D 8 D msec output voltage rise time (time for vo to rise from 10% of v o, nom to 90% of v o, nom ) all t rise D 5 D msec output voltage overshoot ? startup i o = 80% of i o, max ; t a = 25 o c all D D 400 mv input under-voltage lockout all v uvlo turn-on threshold D 34 35.5 v turn-off threshold 32.0 35 D v input over voltage protection all v i, prot D 63 65 v over temperature protection all D 125 D 0 c
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 5 characteristic curves the following figures provide typical characteristics for euk240s9r0 at t a = 25 o c 0 1 2 3 4 5 30 35 40 45 50 55 60 io = 20.5a io = 10.25a io = 0a input current, i in (a) input voltage, v in (v) o utput voltage on/off voltage v on/off (v) (2v/div) v o (v) (5v/div) time, t (5 ms/div) figure 1. typical input characteristics at room temperature . figure 4. typical start-up characteristics from remote on/off. 70 75 80 85 90 95 100 0 5 10 15 20 25 30 35 vin = 60v vin = 48v vin = 36v efficiency, (%) output current, i o (a) output current output voltage i o (a) (5a/div) v o (v) (200 mv/div) time, t (20 s/div) figure 2. typical converter efficiency versus output current at room temperature. figure 5. transient response to a dynamic load change from 50% to 75% 50% of full load. 0 1 2 3 4 5 6 7 8 33 33.5 34 34.5 35 io = 0a io = 10.25a io = 20.5a output ripple voltage v o (v) (50mv/div) time, t (2 s/div) output voltage, v o (v) input voltage, v in (v) figure 3. output ripple voltage at full load and minimum, nominal and maximum input voltage. figure 6. typical output voltage start up vs. input voltage characteristic at room temperature. vin = 60v vin = 48v vin = 36v
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 6 characteristic curves (continued) the following figures provide typical characteristics for euk240s9r0 at t a = 25 o c 6 7 8 9 10 11 12 0 5 10 15 20 25 30 35 vin = 36v vin = 60v vin = 48v 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0 20 30 40 50 60 70 80 90 3 m/s (600lfm) 2 m/s (400lfm) 1 m/s (200lfm) output voltage, v o (v) output current, i o (a) output power. p o (w) local ambient temperature, t a ( c) figure 7. typical output voltage vs. output current characteristic at room temperature. figure 10. thermal derating of the module in the transverse orientation; ai rflow direction from vin(-) to vin(+); vin = 48v. 6 7 8 9 10 11 12 30 35 40 45 50 55 60 65 io = 20.5a io = 10.25a io = 0a 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0 20 30 40 50 60 70 80 90 3 m/s (600lfm) 2 m/s (400lfm) 1 m/s (200lfm) output voltage, v o (v) input voltage, v in (v) output power. p o (w) local ambient temperature, t a ( c) figure 8. typical output voltage vs. input voltage characteristic at room temperature. figure 11. thermal derating of the module in the transverse orientation; ai rflow direction from vin(-) to vin(+); vin = 55v. 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0 20 30 40 50 60 70 80 90 3 m/s (600lfm) 2 m/s (400lfm) 1 m/s (200lfm) output power. p o (w) 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0 20 30 40 50 60 70 80 90 1 m/s (200 lfm) 1.5 m/s (300 lfm) 2 m/s (400 lfm) & 3 m/s ( 600 lfm ) output power. p o (w) local ambient temperature, t a ( c) local ambient temperature, t a ( c) figure 9. thermal derating of the module in the transverse orientation; ai rflow direction from vin(-) to vin(+); vin = 38v. figure 12. thermal derating of the module in the transverse orientation; ai rflow direction from vin(-) to vin(+); vin = 60v.
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 7 test configurations figure 13. input reflected ripple current test setup. figure 14. output ripple and noise test setup. figure 15. output voltage and efficiency test setup. = v o .i o v in .i in x 100 % efficiency safety considerations for safety agency approval the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards, i.e., ul 60950-1, csa c22.2 no. 60950-1- 03, and en60950-1 (vde 0850) (iec60950, 3 rd edition) licensed. the power modules meet the 73/23/eec and 93/68/eec directives and will be marked with the conformite europeane (ce) mark. for the converter output to be considered meeting the requirements of safety extra-low voltage (selv), the input must meet selv requirements. the input to these units is to be provided with a fast- acting fuse with a maximum rating of 15 a in the ungrounded lead .
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 8 feature description remote on/off two remote on/off options are available. positive logic remote on/off turns the module on during a logic-high voltage on the on/off pin, and off during logic low. negative logic remote on/o ff turns the module off during a logic high and on during a logic low. negative logic, device code suffix "1," is the factory-preferred configuration. to turn the power module on and off, the user must supply a swit ch to control the voltage between the on/off terminal and the vi (-) terminal (von/off). the switch can be an open collector or equivalent (see figure 16). a logic low is von/off = -0.3 v to 0.8 v. the maximum ion/off during a logic low is 10 ma. the switch should maintain a logic-low voltage while sinking 10 ma. during logic high, the maximum von/off generated by the power module is 4.7 v. the maximum allowabl e leakage current of the switch at von/off = 2.0v is 0.7 ma. if not using the remote on/off feature, perform one of the following to turn the unit on: for negative logic, short on/off pin to vi(-). for positive logic: leave on/off pin open. v o (+) v o (?) v i (?) + ? i on/off on/off v i (+) loa d v on/off figure 16. circuit configuration for using remote on/off implementation. over-current protection to provide protection in an ou tput overload condition, the module is equipped with internal current-limiting circuitry and can endure current limiting for unlimited duration. if the output current exceeds the current limit inception value, the module enters into the hiccup (auto-restart) mode operatio n, where it shuts down and automatically attempts to restart. as long as the fault condition exists, the module will remain in this hiccup mode, and can sustain this mode of operation until the over-current fault condition is corrected. input under-voltage lockout at input voltages below the input under voltage lockout limit, the module operation is disabled. the module will begin to operate at an input voltage above the under voltage lockout turn-on threshold. over-temperature protection these modules featur e an over-temperature protection circuit to safeguard against thermal damage. the protection circuit shuts down the module when the maximum device reference temperature is exceeded. when the module cools down and the reference device temperature falls below the recovery threshold, the module will resume operation. over-voltage protection the input/output over-voltage protection circuit is designed to shut down the module when the input voltage exceeds the over-voltage threshold. the module will resume operation when the input voltage enters the normal input operating range short circuit protection the power modules shall sustain no damage when subjected to a short circuit of any duration on its output. the output of the module shall recover automatically in a hiccup (auto-restart) manner identical to that described in the over-current protection section. pre-bias immunity the startup/shutdown charac teristics of the module accommodates external voltage source clamping on the output via external diodes without exhibiting non- monotonic startup (see figure 17). the monotonic startup of the module wi ll not be affected by the customer application of t he pre-biasing of the output. during shutdown an internal feature implemented in the module ensures there will be no reverse current. during hiccup operation, the reverse current protection will be enabled. figure 17. pre-bias immunity configuration. module l o a d vs vout
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 9 thermal considerations power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. a reduction in the operating temperature of the module will result in an increase in reliability. the thermal data is based on physical measurements taken in a wind tunnel. the test set-up is shown in figure 18. the module delivers full power over an input voltage range of 36v to 55v, at an ambient temperature of 55 o c, at the airflow rate of 200lfm environment, at sea level, at 50 % relative humidity, with specified orientation. for higher local ambient temperature operation, the modules output power should be derated, as shown in figures 9 - 12. please refer to the application note ?thermal characterization process for open-frame board- mounted power modules? for a detailed discussion of thermal aspects including maximum device temperatures. figure 19. temperature measurement locations air flow x power module w ind tunnel pwbs 6.55 (0.258) 76.2 (3.0) probe location for measuring airflow and ambient temperature 25.4 (1.0) figure 18. thermal test set up.
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 10 post solder cleaning and drying considerations post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. the result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. for guidance on appropriate soldering, cleaning and drying procedures, refer to lineage power board mounted power modules: soldering and cleaning application note (ap01-056eps). through-hole lead-free soldering information the rohs-compliant through-hole products use the sac (sn/ag/cu) pb-free solder and rohs-compliant components. they are designed to be processed through single or dual wave soldering machines. the pins have an rohs-compliant finish that is compatible with both pb and pb-free wave soldering processes. a maximum preheat rate of 3 c/s is suggested. the wave preheat process should be such that the temperature of the power module board is kept below 210 c. for pb solder, the recommended pot temperature is 260 c, while the pb-free solder pot is 270 c max. not all rohs-compliant through-hole products can be processed with paste-through-hole pb or pb-free reflow process. if additional information is needed, please consult with your lineage power representative for more details.
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 11 mechanical outline dimensions are in millimeters and [inches]. tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] ? optional pin lengths shown in table 2, device options. top view side view bottom view
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w lineage power 12 recommended pad layout dimensions are in millimeters and [inches]. tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.]
data sheet march 26, 2008 euk240 series power modules; dc-dc converters 36 ? 60vdc input; 9.6vdc output; 240w document no: ds06-113 ver. 1.03 pdf name: euk240_series_ds.pdf world wide headquarters lineage power corporation 3000 skyline drive, mesquite, tx 75149, usa +1-800-526-7819 (outside u.s.a.: +1-972-284-2626 ) www.lineagepower.com e-mail: techsupport1@lineagepower.com asia-pacific headquarters tel: +65 6416 4283 europe, middle-east and africa headquarters tel: +49 89 6089 286 india headquarters tel: +91 80 28411633 lineage power reserves the right to make changes to the product(s) or information contained herein without notice. no liability is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or information. ? 2008 lineage power corporation, (mesquite, texas) all international rights reserved. ordering information please contact your lineage power sales representativ e for pricing, availabili ty and optional features. table 1. device codes product codes input voltage output voltage output power efficiency connector type comcodes EUK240S9R041Z 36-60 vdc 9.6v 240w 96% through hole cc109114294 euk240s9r0641z 36-60 vdc 9.6v 240w 96% through hole cc109143525 -z indicates rohs compliant modules table 2. device options option suffix negative remote on/off logic 1 auto-restart (must be ordered) 4 pin length: 3.68 mm 0.25mm , (0.145 in. 0.010 in.) 6 pin length: 2.79 mm 0.25mm , (0.110 in. 0.010 in.) 8


▲Up To Search▲   

 
Price & Availability of EUK240S9R041Z

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X